3.1.14. Oil replacement in a mechanical transmission
Unscrew jams of a maslozalivny opening and a drain opening.
Merge oil.
Before installation of a drain stopper, remove parts of metal, from a magnet established on it. Tighten fixing nuts the recommended moment of an inhaling.
Inhaling moment: 32 ±2 N · m.
By means of a lubrikator fill in in a transmission fresh oil.
Fill in the recommended oil until its level will not reach the lower part of a maslozalivny opening.
Recommended transmission oil: transmission oil – classification by API GL (4 or above, viscosity on SAE 75W. 85W or 75W. 90
Volume:
– 2.2L «2WD»;
– 2.3L «(N/A) 4WD»>;
– 2.8L «(T/C) 4WD»;
Tighten a stopper of a maslozalivny opening the recommended moment of an inhaling.
Inhaling moment: 32 ±2 N · m.
|