Repair and Mitsubishi Outlander service since 2003 of release.
1. Operation and car maintenance
2. Engine
3. Transmission
4. Running gear
5. Steering mechanism
6. Brake system
7. Onboard electric equipment
7.1. General information
7.2. Power supply system
7.3. Electrostart-up system
7.4. Ignition system
7.4.1. General information
7.4.2. The operations of maintenance which are carried out directly on the car
7.4.3. Removal of oscillograms of a high voltage with oscillograph use
7.4.4. Examples of oscillograms of a high voltage of faulty system of ignition
7.4.5. Check of the relay of the coil of ignition
7.4.6. Removal and installation of coils of ignition
7.4.7. Removal and installation of the sensor of provision of a camshaft
7.4.8. Removal and installation of the sensor of a detonation
7.4.9. Removal and installation of the lock of ignition
7.4.10. Speedometer check
7.4.11. Tachometer check
7.4.12. Fuel level sensor check
7.5. Lighting system
7.6. Heater, conditioner and ventilation system
8. Body
9. Appendix
10. Electric equipment schemes
 







7-4-4-primery-oscilogramm-vysokogo-napryazheniya-neispravnojj-sistemy-zazhiganiya.html

7.4.4. Examples of oscillograms of a high voltage of faulty system of ignition

Example 1
Examples of oscillograms of a high voltage of faulty system of ignition
The spark category occurs at big tension, duration of the category is small.
Cause of defect – the spark gap is too great.

Example 2
Examples of oscillograms of a high voltage of faulty system of ignition
The spark category occurs at low tension, the back front – flat, duration of the category is great. The final phase of the category is distorted. At such form of a signal admissions of ignition of a working mix are possible.
Cause of defect – the spark gap is too small.

Example 3
Examples of oscillograms of a high voltage of faulty system of ignition
The spark category occurs at low tension, the back front – flat, duration of the category is great. However thus it is not observed signal distortions.
Cause of defect – the spark gap is littered.

Example 4
Examples of oscillograms of a high voltage of faulty system of ignition
The spark category occurs at big tension, duration of the category is small. A difference between this oscillogram and the oscillogram in an example 1 to catch very difficult.
Cause of defect – the wire of a high voltage frayed, contact of tips is broken.

Example 5
Examples of oscillograms of a high voltage of faulty system of ignition
On a site of attenuation there are no fluctuations.
Cause of defect – short circuits of rounds in the ignition coil.