8.2.14. Adjustment of glass of a lateral door
Check smoothness of moving of glass of a door along a directing fillet at a raising and glass lowering before extreme provisions.
In case glass of a door moves up and down not smoothly, make adjustment.
Remove door facing in collecting and a water-proof film.
Weaken screws of fastening of glass of a door through service openings at completely lifted glass of a door and slightly lower door glass.
Completely lift glass of a door and reliably tighten screws of fastening of glass of a door through service openings.
Adjustment at malfunction of a window regulator of a lateral door
NOTE
This adjustment is made, if door glass automatically starts to move down by pressing the switch for a glass raising.
|
Remove door facing in collecting and a water-proof film.
Lower door glass before extreme situation, then disconnect glass from the holder on a window regulator. Lift and lower door glass a hand for check of working effort.
ATTENTION
Establish the soft buffer in a door for prevention of damage of glass at its casual falling.
|
If glass of a door moves up – down not smoothly, execute the following checks and, if necessary, repair details.
Check correctness of installation of a directing fillet of glass of a door.
Eliminate a perekruchivaniye of the top door directing glass.
Check correctness of installation of the bottom door directing glass.
If it is impossible to execute repair or adjustment, replace a door assembled.
Check of operation of the safety mechanism of a window regulator
Place wooden whetstone in thickness about 10 mm, as is shown in drawing then lift door glass.
Check that after a whetstone zazhatiya glass fell approximately by 150 mm. If work of a window regulator does not correspond specified, malfunction of the trailer switch of a window regulator, defect of the socket or a plait of wires, malfunction of the auxiliary switch of a window regulator or the main switch of window regulators, the wrong adjustment of the trailer switch can be the reason.
ATTENTION
If the safety mechanism of a window regulator worked three or more time in a row, it is necessary to make initialization of safety function of a window regulator.
|
|